Ubicación: Global + English
Global Global Algérie Français Algeria English Angola Português Angola English Argentina Español Argentina English Australia English Austria Deutsch Austria English Azerbaijan English Azerbaijan Русский Bahrain English Bangladesh English Belgium English Belgium Français Belgium Nederlands Brazil Português Brazil English Bulgaria български Bulgaria English Cameroon English Cameroon Français Canada English Canada Français Chile Español Chile English China 中文 China 日本語 China English Colombia Español Colombia English Croatia English Czech Republic Čeština Czech Republic English Denmark English Djibouti English Ecuador Español Ecuador English Egypt English Estonia English Ethiopia English Finland Suomi Finland English France Français France English Georgia English Georgia Русский Germany Deutsch Germany English Ghana English Greece Ελληνικά Greece English Guatemala Español Guatemala English Hong Kong, China English Hong Kong, China 中文 Hungary Magyar Hungary English India English Indonesia English Iraq English Ireland English Italy Italiano Italy English Ivory Coast Français Ivory Coast English Japan 日本語 Japan English Jordan English Kazakhstan Русский Kazakhstan English Kenya English Kuwait English Kyrgyzstan Русский Kyrgyzstan English Latvia English Lithuania English Malaysia English Mauritius English Mauritius français (Maurice) Mexico Español Mexico English Moldova Română Moldova English Mongolia English Morocco English Morocco Français Mozambique Português Mozambique English Netherlands Nederlands Netherlands English New Zealand English Nigeria English Norway English Oman English Pakistan English Paraguay Español Paraguay English Peru Español Peru English Philippines English Poland Polski Poland English Portugal Português Portugal English Qatar English Republic of Korea 한국어 Republic of Korea English Romania Română Romania English Saudi Arabia English Serbia Српски Serbia English Singapore English Slovakia English Slovenia English South Africa English Spain English Spain Español Sri Lanka English Sweden English Switzerland Deutsch Switzerland Français Switzerland Italiano Switzerland English Tanzania English Thailand ไทย Thailand English Togo English Togo Français Tunisia English Tunisia Français Türkiye Türkçe Türkiye English Turkmenistan Русский Turkmenistan English Ukraine Українська Ukraine English United Arab Emirates English United Kingdom English Uruguay Español Uruguay English USA English Uzbekistan English Uzbekistan Русский Vietnam Tiếng Việt Vietnam English

UVA protection testing evaluates how effectively sunscreen and daily-use cosmetic products shield the skin from long-wave ultraviolet radiation (320–400 nm), the principal driver of photoaging and persistent pigmentation. Using internationally recognized methods such as ISO 24442 and ISO 24443, accredited third-party laboratories determine the UVA protection factor, critical wavelength, and PA grade needed to substantiate product claims. This article explains the technical principles, sample requirements, test procedures, and regulatory applications of UVA protection measurement for cosmetics.

Technical Overview

UVA radiation spans the wavelength range of 320–400 nm and is conventionally divided into UVA-II (320–340 nm) and UVA-I (340–400 nm). Unlike UVB, UVA penetrates the epidermis deeply into the dermis, passes through window glass, and remains relatively constant throughout the year. Chronic UVA exposure is associated with immediate and persistent pigment darkening, uneven skin tone, loss of elasticity, wrinkle formation, photoimmunosuppression, and contributions to photocarcinogenesis.

Because the erythemal (sunburn) endpoint used for SPF does not capture UVA effects, dedicated UVA protection assessment is required. Two ISO methods form the international backbone of this field: ISO 24442, an in vivo method based on persistent pigment darkening (PPD), and ISO 24443, an in vitro spectrophotometric method using PMMA plates. These methods have been adopted into the EN and GB standard frameworks and are referenced by regulators in the European Union, Asia, and many other markets.

Typical acceptance criteria include a UVA protection factor (UVA-PF) of at least one third of the labeled SPF and a critical wavelength of at least 370 nm, which together define "broad spectrum" and "UVA balanced" protection in major regulatory regimes.

Testing Samples

Sun Care Products

Traditional sun protection products represent the core sample category, including lotions, milks, creams, gels, oils, sticks, and continuous sprays. These products usually carry both SPF and UVA claims and require full UVA characterization before market release.

Decorative Cosmetics with Protection Claims

Foundations, BB creams, CC creams, tinted moisturizers, compacts, and cushion formats that claim SPF or PA protection must also demonstrate UVA efficacy. Pigmented and high-solid formulations require careful sample application on test substrates to ensure uniform films.

Daily Skin Care and Specialty Formats

Day creams, moisturizers, essences, lip care products with SPF claims, after-skin-protection sprays, and products intended for wet skin or water-resistant use fall within the scope of UVA testing. Water-resistant products require additional testing after immersion.

Sample Submission Requirements

  • In vitro testing typically requires a small quantity of product, usually 5–20 g, in the final market formulation and packaging.
  • In vivo testing on a human panel generally requires 30–60 mL of product, depending on the number of test sites and the panel size.
  • Samples should be freshly manufactured, within shelf life, and accompanied by formulation information including UV filters and their concentrations.

Testing Items

UVA protection measurement encompasses several complementary parameters, each addressing a different aspect of performance:

  • UVA Protection Factor (UVA-PF): The ratio of the minimum UVA dose required to produce a defined PPD response on protected skin versus unprotected skin, analogous to SPF but weighted for UVA.
  • Critical Wavelength: The wavelength at which the integral of the absorbance spectrum from 290 nm reaches 90 percent of the total area from 290 to 400 nm; a value of 370 nm or greater indicates broad spectrum protection.
  • UVA/UVB Absorbance Ratio: The ratio of mean UVA absorbance to mean UVB absorbance, which underpins the five-star UVA rating system used in the United Kingdom.
  • PA Grade: The Protection Grade of UPA/UVA label used in Japan, China, and other Asian markets, assigned from UVA-PF or PPD values and expressed as PA+ through PA++++.
  • Water-Resistant UVA-PF: UVA protection retention measured after a standardized immersion protocol, typically 2 × 20 minutes of moderate activity in water.
  • Photostability Assessment: Comparison of absorbance spectra before and after controlled UV pre-irradiation to detect filter degradation.

Testing Methods

In Vivo Persistent Pigment Darkening Method (ISO 24442)

The in vivo method measures UVA protection directly on human volunteers. Test product is applied at 2 mg/cm² to defined areas on the back of volunteers with suitable skin phototypes, typically types III–IV. A series of progressive UVA doses from a filtered xenon source is delivered to both protected and unprotected sites. The persistent pigment darkening response is evaluated during its stable plateau, typically 2–4 hours after exposure. The UVA-PF is calculated as the ratio of the minimal UVA dose producing the PPD threshold on protected skin to that on unprotected skin. Studies must be conducted under ethical approval and informed consent, following the principles of good clinical practice.

In Vitro Diffuse Reflectance Spectrophotometry Method (ISO 24443)

The in vitro method casts the product as a thin film on textured PMMA plates at an application rate of 1.3 mg/cm². The film is pre-irradiated with a calibrated UVA dose from a solar simulator to account for photostability, then UV transmission is measured from 290 to 400 nm using a spectrophotometer equipped with an integrating sphere. An iterative algorithm matches the calculated protection curve to a reference in vivo PPD response to yield a single UVA-PF value. The same final spectrum is used to compute the critical wavelength and the UVA/UVB ratio. The method is widely used for screening formulations, for water-resistance testing, and for routine batch verification, while in vivo confirmation is commonly required for final labeling claims.

Water Resistance and Photostability Protocols

For water-resistance claims, samples are subjected to standardized immersion (commonly two 20-minute cycles with moderate water movement), after which UVA-PF is re-measured and the percentage retention is calculated. A retention of at least 50 percent of the initial UVA-PF is the customary criterion for a water-resistant UVA claim. Photostability is assessed by comparing pre- and post-irradiation spectra from the in vitro procedure.

PA Grading Scheme

  • PA+ corresponds to a PPD or UVA-PF of 2 to less than 4.
  • PA++ corresponds to a value of 4 to less than 8.
  • PA+++ corresponds to a value of 8 to less than 16.
  • PA++++ corresponds to a value of 16 or higher.

Applications

UVA protection testing supports the entire product lifecycle, from research and development to regulatory clearance and market surveillance:

  • Regulatory compliance: Demonstrating UVA-PF at one third of SPF and critical wavelength ≥ 370 nm enables the circular UVA logo on EU labels and broad spectrum claims in other jurisdictions.
  • Market access in Asia: PA grading substantiates the protection labeling required for sunscreen registration in China, Japan, Korea, and Southeast Asian markets, where ISO-based methods are incorporated into national GB and JIS-aligned frameworks.
  • Formulation development: In vitro screening allows rapid comparison of UV filter combinations, boosting systems, and film formers, and identifies photostability problems early.
  • Claim substantiation: Retailers, e-commerce platforms, and advertising regulators increasingly require objective UVA data to support marketing claims.
  • Quality control and post-market surveillance: Periodic batch verification by accredited third-party laboratories confirms that production remains consistent with the tested reference formulation.
  • Comparative benchmarking: Manufacturers use UVA spectra and ratings to position products against competitors and to support premium "anti-photoaging" claims.

FAQ

What is the difference between SPF and UVA-PF?

SPF measures protection against UVB-induced sunburn (erythema), while UVA-PF measures protection against UVA-induced persistent pigment darkening. A product with a high SPF but inadequate UVA-PF may still allow significant UVA damage, which is why both parameters must be evaluated.

Why is the 370 nm critical wavelength threshold important?

The critical wavelength indicates how far into the UVA band a product's protection extends. Reaching 370 nm means 90 percent of the absorbed energy lies below that wavelength, demonstrating balanced coverage of both UVB and the longer UVA-I rays most responsible for photoaging.

When is in vivo testing required versus in vitro testing?

In vitro testing per ISO 24443 is suitable for screening, optimization, water-resistance evaluation, and routine control. In vivo testing per ISO 24442 is generally required to substantiate final UVA-PF or PA labeling claims for regulatory submissions in many markets.

How long does UVA protection testing take?

In vitro testing typically completes within one to two weeks. In vivo studies require panel recruitment and ethical scheduling and usually take three to six weeks. Water-resistance variants add immersion time and re-measurement to the schedule.

Do water-resistant products need separate UVA testing?

Yes. If a water-resistance claim includes UVA protection, UVA-PF must be re-measured after the standardized immersion protocol, and the retained protection must meet the applicable threshold for the claim to be valid.